Test Code LAB0205245 Creatinine Clearance 24 hour
Additional Codes
EPIC Test Codes | |
---|---|
LAB0205245 | CREATININE CLEARANCE 24 HOUR |
Reporting Title
Creatinine Clearance 24 hour
Methodology
Alkaline Picrate
Performing Laboratory
Rice Memorial Hospital
Specimen Requirements
Plasma/serum and urine are required. Plasma/serum specimen should preferably be obtained at mid-point of the 24-hour period of urine collection.
Specimen Type: Plasma or serum
Container/Tube:
Plasma: Heparin, plain or gel separator
Serum: Clot, plain, activator or gel separator
Specimen Volume: 0.5 mL
Specimen Minimum Volume: 0.1 mL
Collection Instructions:
1. No preservative is required (10 g boric acid or 30 mL 6N HCL may be used as an alternative).
2. Instruct patient to void at the beginning of the collection period and discard the specimen.
3. Collect all urine, including the final specimen voided at the end of the collection period.
4. Measure and record urine volume, date and time collected, and collection interval.Container/Tube: Collection container (available from Rice Lab)
5. Aliquot 5 mL of well mixed specimen into a transport tube.
Additional Information: Total volume and patient’s height and weight are required.
Specimen Transport Temperature
Refrigerated (preferred)up to 6 days/Frozen up to 6 months/Ambient up to 2 days
Reference Values
66.00-164.00 mL/min
Day(s) Test Set Up
Monday through Sunday
CPT Coding
82575-Creatinine clearance
81050-Urine timed measurement (if appropriate)