Sign in →

Test Code LAB0230284 Folate

Additional Codes

EPIC Test Codes
LAB0230284 FOLATE

 

Reporting Title

Folate

Methodology

Chemiluminescence

Performing Laboratory

Rice Memorial Hospital

Specimen Requirements

Specimen Type: Plasma or serum

Container/Tube:

Plasma: Lithium heparin, plain or gel separator

Serum: Clot, plain, activator or gel separator

Specimen Volume: 1 mL

Specimen Minimum Volume: 0.5 mL

Collection Instructions:

1. Fasting preferred.

2. Protect from light.

Additional Information: Hemolyzed samples are not acceptable.

Specimen Transport Temperature

Refrigerated (preferred) up to 7 days/Frozen  up to 30 days

Reference Values

7.0-31.4 ng/mL

Day(s) Test Set Up

Monday through Friday

CPT Coding

82746