Sign in →

Test Code LAB0290718 D-Dimer

Additional Codes

EPIC Test Codes
LAB0290718 D DIMER

 

Reporting Title

D-Dimer

Methodology

Immunoturbidimetric Assay

Performing Laboratory

Rice Memorial Hospital

Specimen Requirements

Specimen Type: Platelet-poor citrated plasma

Collection Container/Tube: Citrate tube (3.2%) tube, properly filled

Submission Container/Tube: Plastic transport tube

Specimen Volume: 1 mL

Specimen Minimum Volume: 0.5 mL

Additional Information: Separation of plasma within 24 hours of collection is recommended.

Specimen Transport Temperature

Frozen up to 2 weeks at -20°C

Reference Values

0.0-500.0 ng/mL FEU

Day(s) Test Set Up

Monday through Sunday

CPT Coding

85379